null
Allegro

Allegro 20″ Axial Explosion-Proof (EX) High Output Metal Blower | 9525-50EX

Allegro 20″ Axial Explosion-Proof (EX) High Output Metal Blower | 9525-50EX

$2,869.33
  • SKU: 9525-50EX
In Stock & Ready To Ship!
Current Stock:Only left:
Description

Designed for applications requiring a maximum amount of output. Made from 16-gauge cold rolled steel housing and powder-coated in safety orange with 3 blade impeller. Powered by a 1 ½ hp, 3450 RPM, UL listed and CSA certified motor. Comes with an interchangeable flange for intake or exhaust mounting, integrated carry handles for easy transport, a steel/zinc plated grill and four rubber feet are added features of this powerhouse unit.

CONSTRUCTION:

  • Complete unit epoxy powder-coated in orange
  • Interchangeable flange for intake or exhaust side mounting
  • 16-gauge cold rolled steel housing
  • Integrated carry handles
  • Steel grill (zinc plated), equipped with four rubber feet
  • Duct grounding lug
  • NOTE: EX blowers require an explosion-proof socket (PN 9503-03: 125V)
  • Cord: 25’ (7.63 m) 12/3 AWG SOOW 600V
  • Plug: NEMA 20 Amp, 125V, Explosion-Proof

MOTOR:

  • HP: 1 ½ HP
  • Certifications: UL Listed, CSA Certified
  • Voltage/Hz : 115/208-230V AC, 60 Hz, Single Phase
  • RPM: 3450
  • Current Draw: 15.4/8.4-7.7A
  • Protection: Thermal, Automatic Reset

FAN:

  • Anti-Static glass reinforced polyamide (PAGAS) three blade fan with aluminum hub

ACCESSORIES:

DUCTING:

  • Black, single-ply, neoprene coated, statically conductive vinyl/polyester material, temp. resistant up to 250° F (121.1° C)
  • Retractable, non-collapsible design, Class 1 hard drawn spring steel wire helix (meets ASTM 227 specs)
  • Grounding cable on both ends
  • WARNING: When using statically conductive ducting, the integrated grounding wire must be properly grounded to the blower chassis OR linked to any additional grounding wire or duct used (as shown). Refer to User Manual for detailed instructions.

EX Rated Receptacle

  • Iron mounting box with triple coat finish and spring-loaded door to keep out dust when in use. When plug is not in use, a neoprene gasket inside receptacle seals around plug to keep out dirt, water, dust, etc.
    • 9503-03: 125V only

EX Rated Extension Cords

    • 9540-50EX: 125V

 

HAZARDOUS LOCATION RATING:

Motors EX Plugs
Class I, Groups C, D; Class II, Groups F, G Class I, Div. 1&2, Groups B, C, D; Class II, Div. 1&2, Groups F, G

 

BLOWER DIMENSIONS:

Length Width Height Weight
19” (48.2 cm) 22” (55.8 cm) 22 ½” (57.1 cm) 79 lbs. (35.8 kg)

 

*FLOW RATES: (CFM calculated using 15’ (4.75 m) of 20” (50.8 cm) ducting)

Free Air One 90° Bend Two 90° Bends
6468 CFM (10989 m3/hr) 4314 CFM (7330 m3/hr) 3922 CFM (6664 m3/hr)